Anaeston 5000 Series Anaesthetic Machine

ANAESTON 5000 Series
  • Single (O2), double (O2 +N2O) or triple (O2+N2O+air) gas source models available for option
  • Dual flowmeters for each gas source with more precise adjustment for low-flow anaesthesia
  • Tidal volume setting from 20 to 1500ml, applicable for adult, pediatric and neonate
  • Dynamic tidal volume feedback and compensation with precise control
  • Abundant ventilation modes (differed from model to model)
  • Double vaporizer positions, compatible with Enflurane, Sevoflurane, Isoflurane, Halothane and Desflurane of SELECTATEC interface
  • Pressure differential flow sensor with variable diameters, automatically adaptive for adult, pediatric and neonate modes
  • High efficiency double-layer CO2 absorbers with high efficiency
  • Modular compact airway circuit with minimal dead space and low condensation
  • Optional backup cylinder system with pressure regulator
  • RS-232 interface available
ANAESTON 5000/L  
Standard Ventilation Modes
  • VCV
 
  • PCV
 
  • PLV
 
  • Manual
Auxiliary Modes
  • SIGH
 
  • EIP
 
  • PEEP
Optional Modules
  • SIMV Module
 
  • SIMV-VCV
 
  • SIMV-PCV
 
  • PSV
 
  • EtCO2 Module
 
  • EtCO2 Value
 
  • ICO2 Value
 
  • Trend
 
  • CSM Module
 
  • CSI Value
 
  • EMG Value
 
  • BS Value
 
  • SQI Value
 
  • EEG Value
 
  • Trend
Display Modes
  • Bracket-mounted 12.1” high resolution colourful TFT display
 
  • Simple operating interface to set all 10 parameters within the main menu
 
  • Synchronous display 3-channel waveforms of P-T, V-T and F-T with customizable sequence (CSI, EEG, and ETCO2 waveforms optional)
 
  • Large Font display of real-time parameter values with upper and lower limits
 
  • P-V, F-V and P-F loops display (Max. 2 loops display synchronously)
 
  • Switchable to trend curve and CSM (optional) parameters display
 
  • Remarkable display for classified alarm events with different indicating lights
ANAESTON 5000/P  
Standard Ventilation Modes
  • VCV
 
  • PLV
 
  • Manual
Auxiliary Modes
  • SIGH
 
  • EIP
 
  • PEEP
Optional Modules
  • PCV Module
 
  • Waveform & Loop Module
 
  • SIMV Module
 
  • SIMV-VCV
 
  • SIMV-PCV
 
  • PSV
Display Modes
  • Bracket-mounted 5.7” high resolution colourful TFT display
 
  • 5 shortcut keys for easy parameter setting
 
  • Display of real-time parameter values with upper and lower limits
 
  • 1-channel of P-T waveform display as standard interface
 
  • Switchable to the following display modes (requiring optional modules)

2-channel waveforms

2-channel waveforms & 1 loop

2 loops

 
  • Display of multiple alarm events
ANAESTON 5000/S  
Standard Ventilation Modes
  • VCV
 
  • PLV
 
  • Manual
Auxiliary Modes
  • SIGH
 
  • EIP
Display Modes
  • Bracket-mounted 5.7” high resolution colourful TFT display
 
  • 4 parameter settings: tidal volume (Vt), breathing rate, I:E ratio and pressure limit
 
  • Display of real-time parameter values with upper and lower limits
 
  • 1-channel of P-T waveform display
 